This work presents a data-driven approach for diagnosing sensor faults and leaks in hydraulic pipelines using neuro-fuzzy Zonotopic Kalman Filters (ZKF). The approach involves two key steps: first, identifying the nonlinear pipeline system using an adaptive neuro-fuzzy inference system (ANFIS), resulting in a set of Takagi–Sugeno fuzzy models derived from pressure and flow data, and second, implementing a neuro-fuzzy ZKF bench to detect pipeline leaks and sensor faults with adaptive thresholds. The learning phase of the neuro-fuzzy systems considers only fault-free data. Fault isolation is achieved by comparing zonotopic sets and evaluating a fault signature matrix. The method accounts for parametric uncertainty and measurement noise, ensuring robustness. Experimental validation on a hydraulic pipeline demonstrated high precision (up to 99.24%), recall (up to 99.20%), and low false positive rates (as low as 0.76%) across various fault scenarios and operational points.
No takes yet. Share an insight, caveat, or question.
Pérez-Pérez et al. (2024) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: