Key result
In patients undergoing tricuspid transcatheter edge-to-edge repair, transvalvular CIED leads were associated with a higher risk of residual Grade IV tricuspid regurgitation (RR 2.02).
Why the study?
Many patients undergoing tricuspid TEER have transvalvular CIED leads, raising concerns regarding leaflet grasping, residual tricuspid regurgitation, and clinical outcomes.
Does tricuspid TEER improve TR severity in adult patients with transvalvular CIED leads compared to those without CIED leads?
Meta-Analysis (n=1,825)
Does tricuspid TEER improve TR severity in adult patients with transvalvular CIED leads compared to those without CIED leads?
Answers are grounded in this paper and cite their sources.
In patients undergoing tricuspid TEER, transvalvular CIED leads do not preclude meaningful TR reduction or clinical stability, though they may predispose to residual Grade IV TR.
Background A substantial proportion of patients undergoing tricuspid transcatheter edge-to-edge repair (TEER) have transvalvular cardiac implantable electronic device (CIED) leads, raising concern about leaflet grasping, residual tricuspid regurgitation (TR), and clinical outcomes. Methods Using PRISMA methodology, we performed a systematic review and meta-analysis of studies identified in PubMed, Scopus, Web of Science, and the Cochrane Library from inception through December 2025. We included studies comparing tricuspid TEER outcomes in adults with transvalvular CIED leads versus those without CIEDs. The primary outcome was post-TEER TR severity (grades I–V), while secondary outcomes included procedure duration, all-cause mortality and tricuspid valve reintervention. Pooled estimates were calculated using random-effects models with restricted maximum likelihood (REML). Results Five eligible studies (n = 1825; 628 with CIED, 1197 without) were included. Post-TEER TR grades I–III did not differ between groups (Grade I: RR 0.93, 95% CI 0.77–1.13; Grade II: RR 0.95, 95% CI 0.81–1.12; Grade III: RR 1.13, 95% CI 0.88–1.46). Patients with CIED leads had a higher risk of residual TR Grade IV (RR 2.02, 95% CI 1.23–3.32), while Grade V did not differ (RR 1.81, 95% CI 0.64–5.16). Procedure duration was similar (MD − 7.90 min, 95% CI − 24.22 to 8.41), as were all-cause mortality (RR 0.97, 95% CI 0.61–1.54) and TV reintervention (RR 1.31, 95% CI 0.54–3.18). Conclusions In selected patients undergoing tricuspid TEER, transvalvular CIED leads do not appear to preclude meaningful TR reduction or clinical stability. However, lead-bearing anatomy may still predispose to residual Grade IV TR, supporting careful, mechanism-based Heart Team assessment for patient selection and procedural planning.
No takes yet. Share an insight, caveat, or question.
Gadelmawla et al. (2026) conducted a meta-analysis in Tricuspid regurgitation (n=1,825). Transvalvular cardiac implantable electronic device (CIED) leads vs. No CIED leads was evaluated on Post-TEER TR severity Grade IV (RR 2.02, 95% CI 1.23-3.32, p=<0.01). In patients undergoing tricuspid transcatheter edge-to-edge repair, transvalvular CIED leads were associated with a higher risk of residual Grade IV tricuspid regurgitation (RR 2.02).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: