Key result
A longer (3.5 vs 2.2 cm, p<0.01) and deeper (0.94 vs 0.49 cm, p<0.01) cavotricuspid isthmus was significantly associated with unsuccessful radiofrequency catheter ablation for common atrial flutter.
Why the study?
Does right atrial anatomy affect the outcome of radiofrequency catheter ablation for common atrial flutter?
Observational (n=20)
Does right atrial anatomy affect the outcome of radiofrequency catheter ablation for common atrial flutter?
A longer and deeper cavotricuspid isthmus, along with a higher eustachian valve, is associated with a higher likelihood of unsuccessful or difficult radiofrequency catheter ablation for common atrial flutter.
Radiofrequency catheter ablation (RFCA) targeting the cavotricuspid isthmus is usually an effective treatment for common atrial flutter (AFL), except in a small subset of patients and the reason for this has yet to be elucidated. The present study investigated the relationship between the outcome of RFCA for common AFL and the anatomy of the right atrium as seen on angiography. Twenty consecutive patients who underwent RFCA for common AFL were divided into 2 groups according to the results of RFCA. Group A comprised 13 patients whose AFL was abolished, fulfilling the criteria of success by the conventional catheter approach, and group B comprised 7 patients whose AFL could not be abolished according to the criteria for success (n=4) or was abolished following an additional superior vena cava approach (n=3). On angiography, the cavotricuspid isthmus was longer (3.5+/-0.5 vs 2.2+/-0.6 cm) and deeper (0.94+/-0.35 vs 0.49+/-0.19 cm) in group B than in group A (both p<0.01). The height of the eustachian valve was also greater in group B than in group A (1.4+/-1.1 vs 0.48+/-0.48 cm, p<0.02). These results suggest that the anatomical structure of the cavotricuspid isthmus affects the outcome of RFCA for common AFL.
No takes yet. Share an insight, caveat, or question.
Ohba et al. (2000) conducted an observational in Common atrial flutter (n=20). Right atrial anatomical structure (cavotricuspid isthmus and eustachian valve) was evaluated on Cavotricuspid isthmus length and depth (p=<0.01). A longer (3.5 vs 2.2 cm, p<0.01) and deeper (0.94 vs 0.49 cm, p<0.01) cavotricuspid isthmus was significantly associated with unsuccessful radiofrequency catheter ablation for common atrial flutter.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: