Few data are available on the uptake by the human gut of the element technetium. Of current radiological interest in connection with discharges of technetium-99 in liquid discharges from BNFL, Sellafield, is uptake from European lobsters (Homarus gammarus), whose edible parts are known to concentrate technetium. In this study, a group of eight adult volunteers (six males and two females) ate samples of edible flesh from lobsters caught off the west Cumbrian coast and provided 24 h samples of urine and faeces for analysis. Detection of uptake from the gut by difference between intake and faecal measurements proved insensitive, suggesting a low value of the gut transfer factor (f1 value) of up to 0.1 with a maximum (two standard deviations) level of about 0.3. In urine, technetium was detectable at a relatively low level compared with the intakes, consistent with a low absorption across the gut. Values for f1 were derived with the aid of literature data for excretion following intravenous administration of technetium-95 m as pertechnetate, and gave averaged data for f1 in the range 0.046 to 0.23. These results are in broad conformity with those derived from the faecal measurements, and suggest a lower value than the 0.5 used by ICRP.