Key result
A deep learning model using the 12-lead ECG identified elevated mean pulmonary capillary wedge pressure (>15 mmHg) with an AUC of 0.79 ± 0.01 in the holdout set.
Why the study?
Central hemodynamic parameters are typically measured invasively via pulmonary artery catheterization, which involves patient risk and is not routinely available in all settings.
Can a deep learning model applied to a 12-lead ECG accurately identify elevated mean pulmonary capillary wedge pressure?
Observational (n=248,955)
No
Can a deep learning model applied to a 12-lead ECG accurately identify elevated mean pulmonary capillary wedge pressure?
Effect estimate: AUC 0.79 ± 0.01
A deep learning model can noninvasively infer elevated pulmonary capillary wedge pressure from a standard 12-lead ECG, offering a potential alternative when invasive monitoring is unavailable.
Background: Central hemodynamic parameters are typically measured via pulmonary artery catherization-an invasive procedure that involves some risk to the patient and is not routinely available in all settings. Objectives: This study sought to develop a noninvasive method to identify elevated mean pulmonary capillary wedge pressure (mPCWP). Methods: We leveraged data from 248,955 clinical records at the Massachusetts General Hospital to develop a deep learning model that can infer when the mPCWP >15 mmHg using the 12-lead electrocardiogram (ECG). Of these data, 242,216 records were used to pre-train a model that generates useful ECG representations. The remaining 6,739 records contain encounters with direct measurements of the mPCWP. Eighty percent of these data were used for model development and testing (5,390), and the remaining records comprise a holdout set (1,349) that was used to evaluate the model. We developed an associated unreliability score that identifies when model predictions are likely to be untrustworthy. Results: The model achieves an area under the receiver operating characteristic curve (AUC) of 0.80 ± 0.02 (test set) and 0.79 ± 0.01 (holdout set). Model performance varies as a function of the unreliability, where patients with high unreliability scores correspond to a subgroup where model performance is poor: for example, patients in the holdout set with unreliability scores in the highest decile have a reduced AUC of 0.70 ± 0.06. Conclusions: The mPCWP can be inferred from the ECG, and the reliability of this inference can be measured. When invasive monitoring cannot be expeditiously performed, deep learning models may provide information that can inform clinical care.
No takes yet. Share an insight, caveat, or question.
Schlesinger et al. (2022) conducted an observational in Elevated mean pulmonary capillary wedge pressure (n=248,955). Deep learning model using 12-lead ECG vs. Direct measurement of mPCWP was evaluated on Inference of mPCWP >15 mmHg (AUC 0.79 ± 0.01). A deep learning model using the 12-lead ECG identified elevated mean pulmonary capillary wedge pressure (>15 mmHg) with an AUC of 0.79 ± 0.01 in the holdout set.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: