This Technical Brief is Part II of a two-part study concerning water single-phase pressure drop and heat transfer in an array of staggered micro-pin-fins. This brief reports the pressure drop results. Both adiabatic and diabatic tests were conducted. Six previous friction factor correlations for low Reynolds number (Re<1000) flow in conventional and micro-pin-fin arrays were examined and found underpredicting the adiabatic data except the correlation by Short et al. (2002, “Performance of Pin Fin Cast Aluminum Coldwalls, Part 1: Friction Factor Correlation,” J. Thermophys. Heat Transfer, 16(3), pp. 389–396), which overpredicts the data. A new power-law type of correlation was developed, which showed good agreement with both adiabatic and diabatic data.
No takes yet. Share an insight, caveat, or question.
Qu et al. (2008) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: