Key result
Applying elastic wraps for practical blood flow restriction training based on 10-30% of the resting limb circumference is recommended as a valid and safe technique.
Why the study?
Studies on practical blood flow restriction (pBFR) training have used inconsistent techniques to apply the pressure exerted by elastic wraps, lacking consensus compared to traditional BFR training.
Answers are grounded in this paper and cite their sources.
Limb circumference is the best predictor of arterial occlusion pressure for prescribing practical blood flow restriction training using elastic wraps.
Most studies with blood flow restriction (BFR) training have been conducted using devices capable of regulating the restriction pressure, such as pneumatic cuffs. However, this may not be a viable option for the general population who exercise in gyms, squares and sports centers. Thinking about this logic, practical blood flow restriction (pBFR) training was created in 2009, suggesting the use of elastic knee wraps as an alternative to the traditional BFR, as it is low cost, affordable and practical. However, unlike traditional BFR training which seems to present a consensus regarding the prescription of BFR pressure based on arterial occlusion pressure (AOP), studies on pBFR training have used different techniques to apply the pressure/tension exerted by the elastic wrap. Therefore, this Current Opinion article aims to critically and chronologically examine the techniques used to prescribe the pressure exerted by the elastic wrap during pBFR training. In summary, several techniques were found to apply the elastic wrap during pBFR training, using the following as criteria: application by a single researcher; stretching of the elastic (absolute and relative overlap of the elastic); the perceived tightness scale; and relative overlap of the elastic based on the circumference of the limbs. Several studies have shown that limb circumference seems to be the greatest predictor of AOP. Therefore, we reinforce that applying the pressure exerted by the elastic for pBFR training based on the circumference of the limbs is an excellent, valid and safe technique.
No takes yet. Share an insight, caveat, or question.
Aniceto et al. (2022) conducted a review in Individuals undergoing blood flow restriction training. Practical blood flow restriction (pBFR) training using elastic wraps was evaluated. Applying elastic wraps for practical blood flow restriction training based on 10-30% of the resting limb circumference is recommended as a valid and safe technique.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: