Theoretical and experimental analysis quantifies voltage unbalance effects on induction motors, suggesting significant operational impacts.
Voltage unbalance is one of the power quality problems causing a lot of ill effects on induction motors. These are namely: Overheating, line-current unbalance, derating, torque pulsation, and inefficiency. The objective of the present work is to assess and quantify the effects of voltage unbalance on induction motors using both theory and experimentation. The analytical study is performed using the complex voltage unbalance factor model of this problem. The work deals specifically with the influence of the variations in the complex angle of the voltage unbalance factor on the stator and rotor currents, stator and rotor copper losses and total losses. The experimental investigation is carried out using an apparatus that measures currents, torque and power losses.
No takes yet. Share an insight, caveat, or question.
Dekhandji et al. (2019) studied this question.