Key result
Having one or more high-sensitivity troponin T readings ≥ 10 ng/L was associated with a significantly increased risk of 30-day major adverse cardiac events compared to readings < 5 ng/L (OR 10.3).
Why the study?
Prognostic thresholds for 30-day MACE have been studied for hsTnT in suspected ACS, but data on its prognostic performance for one-year MACE are limited.
Does high-sensitivity troponin T (hsTnT) measurement predict 30-day and one-year MACE in patients presenting with suspected acute coronary syndrome?
Cohort (n=2,444)
No
Does high-sensitivity troponin T (hsTnT) measurement predict 30-day and one-year MACE in patients presenting with suspected acute coronary syndrome?
Odds Ratio: 10.3 (95% CI 7.83–13.64)
Absolute Event Rate: 33.5% vs 4.7%
p-value: p=<0.001
Absolute hsTnT levels ≥ 30 ng/L or a 2-hour delta ≥ 10 ng/L provide strong positive predictive value for 30-day and 1-year MACE in patients with suspected ACS.
hsTnT ≥10 ng/L may refine 30-day prognosis in suspected ACS; extends serial cut-off validation but should not yet alter practice.
INTRODUCTION: Prognostic thresholds for 30-day major adverse cardiac events (MACE) have been studied for high-sensitivity troponin T (hsTnT) in patients with suspected acute coronary syndrome (ACS), but there is limited data on the prognostic performance of hsTnT for one-year MACE. METHODS: We prospectively measured hsTnT (in ng/mL up to two decimal places) at 0, 2 and 7 hours for patients presenting with symptoms suggestive of ACS to our emergency department from March 2010 to April 2013. We assessed the prognostic performance of hsTnT cut-offs for 30-day and one-year MACE, and the utility of delta-hsTnT in predicting MACE. RESULTS: Among 2,444 patients studied, 273 (11.2%) developed MACE (including index MACE) by 30 days and 359 (14.7%) patients developed MACE at one year. The suggested hsTnT cut-off for 30-day MACE was ≥ 10 ng/L at 0 hour (positive predictive value [PPV] 33.5%, negative predictive value [NPV] 94.5%) and 7 hours (PPV 37.3%, NPV 94.5%), and ≥ 20 ng/L at 2 hours (PPV 36.9%, NPV 96.9%). For one-year MACE, the suggested cut-off was also ≥ 10 ng/L at all readings. Plasma hsTnT ≥ 30 ng/L at any reading gave PPV > 54% and NPV > 93% for 30-day MACE. Absolute 0-2 hour and 2-7 hour delta-hsTnT ≥ 10 ng/L gave PPV > 50% for 30-day and one-year MACE. CONCLUSION: Patients with 0-, 2- or 7-hour hsTnT ≥ 30 ng/L and 0-2 hour delta-hsTnT ≥ 10 ng/L had PPV > 50% for 30-day and one-year MACE, and should be investigated thoroughly.
No takes yet. Share an insight, caveat, or question.
Lin et al. (2019) conducted a cohort in Suspected acute coronary syndrome (ACS) (n=2,444). High-sensitivity troponin T (hsTnT) ≥ 10 ng/L vs. hsTnT < 5 ng/L was evaluated on Major adverse cardiac events (MACE) within 30 days (OR 10.3, 95% CI 7.83-13.64, p=<0.001). Having one or more high-sensitivity troponin T readings ≥ 10 ng/L was associated with a significantly increased risk of 30-day major adverse cardiac events compared to readings < 5 ng/L (OR 10.3).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: