Key result
Artificial intelligence-enabled electrocardiography demonstrated high discrimination for hyperkalemia detection, with AUROCs frequently between 0.8 and 0.95, but low positive predictive values indicate it currently serves as a rule-out triage tool rather than a replacement for laboratory testing.
Why the study?
Laboratory potassium measurement is the diagnostic reference standard but is not always immediately available for rapid clinical decisions, prompting the evaluation of AI-enabled ECG as a non-invasive tool while awaiting laboratory confirmation.
Does artificial intelligence-enabled electrocardiography accurately detect and estimate potassium abnormalities in adult patients compared to laboratory reference standards?
Systematic Review (n=33)
Does artificial intelligence-enabled electrocardiography accurately detect and estimate potassium abnormalities in adult patients compared to laboratory reference standards?
AI-ECG shows promise as a non-invasive triage and rule-out tool for detecting potassium abnormalities, particularly hyperkalemia, but requires prospective external validation and workflow-impact studies before routine clinical implementation.
Laboratory measurement of serum, plasma, or whole-blood potassium remains the reference standard for diagnosing hyperkalemia and hypokalemia, yet results are not always immediately available when rapid clinical decisions are required. Artificial intelligence-enabled electrocardiography (AI-ECG) has been proposed as an early, non-invasive tool that may identify potassium abnormalities while laboratory confirmation is pending. This systematic review evaluated adult studies published between 2016 and 2026 in which AI or machine-learning (ML) techniques were applied to ECGs to detect hyperkalemia or hypokalemia, classify potassium status, or estimate continuous potassium concentration, always against a paired laboratory potassium reference standard. We searched multiple biomedical, preprint, trial, and citation databases through June 18, 2026, following PRISMA-DTA, PRISMA 2020, and PRISMA-S reporting principles. Methodological quality was assessed with QUADAS-2. Of 366 records assessed for eligibility, 33 peer-reviewed primary AI/ML studies were included. Hyperkalemia detection dominated the evidence base, with many externally or internally validated studies reporting area under the receiver operating characteristic curve (AUROC) in the high 0.8 to mid-0.9 range, whereas evidence for hypokalemia detection, categorical potassium-status classification, and continuous potassium estimation remained overlapping and more heterogeneous. Although reported performance was often encouraging, overall risk of bias was low in only four studies, unclear in 23, and high in six. Considerable heterogeneity in potassium thresholds, ECG modalities, validation strategies, reporting units, and performance metrics precluded meta-analysis. Overall, the available evidence suggests that AI-ECG is a promising investigational adjunct for triage, monitoring, and clinical decision support, primarily serving as a rule-out tool rather than a replacement for laboratory potassium testing. Its clinical utility may be particularly relevant in higher-prevalence populations, such as patients with chronic kidney disease or those receiving dialysis, where positive predictive value and monitoring yield may be more favorable. Prospective external validation, calibration, subgroup reporting, reproducibility, and workflow-impact studies are needed before routine clinical implementation.
No takes yet. Share an insight, caveat, or question.
Kaur et al. (2026) conducted a systematic review in Potassium abnormalities (hyperkalemia and hypokalemia) (n=33). Artificial intelligence-enabled electrocardiography (AI-ECG) vs. Laboratory potassium measurement was evaluated on Diagnostic accuracy (AUROC) for potassium abnormality detection. Artificial intelligence-enabled electrocardiography demonstrated high discrimination for hyperkalemia detection, with AUROCs frequently between 0.8 and 0.95, but low positive predictive values indicate it currently serves as a rule-out triage tool rather than a replacement for laboratory testing.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: