Key result
Higher preprocedural FT4 levels within the normal range independently predicted atrial fibrillation recurrence after cryoballoon ablation (HR 1.187; 95% CI 1.093-1.290; p<0.001).
Why the study?
The association between elevated FT4 concentration within the normal range and AF recurrence after cryoballoon ablation in China was unknown.
Does a higher FT4 level within the normal range predict atrial fibrillation recurrence after cryoballoon ablation in patients without structural heart disease?
Observational (n=453)
Does a higher FT4 level within the normal range predict atrial fibrillation recurrence after cryoballoon ablation in patients without structural heart disease?
Higher preprocedural FT4 levels within the normal range independently predict AF recurrence after cryoballoon ablation in patients with paroxysmal AF without structural heart disease.
Answers are grounded in this paper and cite their sources.
Normal-range FT4 should not guide ablation decisions; leaves open whether thyroid status modulates post-ablation AF recurrence.
BACKGROUND: Accumulated evidence has indicated that a high-normal FT4 level is an independent risk factor for the clinical progression of AF. However, the association between elevated FT4 concentration within the normal range and AF recurrence after cryoballoon ablation in China is unknown. METHODS: This retrospective and observational study included 453 AF patients who underwent cryoballoon ablation from January 2016 to August 2018. Patients were classified into quartiles based on preprocedural serum FT4 concentration. The clinical characteristics of the patients and the long-term rate of AF recurrence after ablation were assessed. RESULTS: After a mean follow-up period of 17.4 ± 9.0 months, 91 (20.1%) patients suffered from AF recurrence. The AF recurrence rate by FT4 quartile was 17.7%, 19.0%, 21.4%, and 22.3% for participants with FT4 in quartile 1, 2, 3, and 4, respectively (p < .001). On multivariate Cox regression, FT4 concentration (HR: 1.187, 95% CI: 1.093-1.290, p < .001) and left atrial diameter (HR: 1.052, 95% CI: 1.014-1.092, p = .007) were significant predictors of AF recurrence. When stratifying for AF type, the rate of postoperative recurrence was independently increased as FT4 concentration increased in paroxysmal AF, but not in persistent AF (p < .001 in paroxysmal AF and p = .977 in persistent AF). CONCLUSION: Higher FT4 level within the normal range predicted the outcome of cryoballoon ablation in Chinese paroxysmal AF patients without structural heart disease.
No takes yet. Share an insight, caveat, or question.
Pei et al. (2021) conducted an observational in Atrial fibrillation (n=453). Higher preprocedural serum FT4 concentration vs. Lower FT4 concentration was evaluated on Atrial fibrillation recurrence (HR 1.187, 95% CI 1.093-1.290, p=<.001). Higher preprocedural FT4 levels within the normal range independently predicted atrial fibrillation recurrence after cryoballoon ablation (HR 1.187; 95% CI 1.093-1.290; p<0.001).
Synapse has enriched 10 related papers. Consider them for comparative context: