Key result
High-resolution CINE MRI detects post-MI diastolic dysfunction missed by Doppler ultrasound.
Why the study?
Does high-temporal-resolution CINE MRI improve the detection of diastolic dysfunction compared to Doppler ultrasound in a mouse model of myocardial infarction?
Does high-temporal-resolution CINE MRI improve the detection of diastolic dysfunction compared to Doppler ultrasound in a mouse model of myocardial infarction?
High-temporal-resolution CINE MRI demonstrates superior sensitivity compared to Doppler ultrasound for detecting diastolic dysfunction in a mouse model of myocardial infarction.
High-temporal-resolution CINE MRI may improve preclinical detection of post-MI diastolic dysfunction; leaves open clinical translation.
Diastolic dysfunction is a sensitive early indicator of heart failure and can provide additional data to conventional measures of systolic function. Transmitral Doppler ultrasound, which measures the one-dimensional flow of blood through the mitral valve, is currently the preferred method for the measurement of diastolic function, but the measurement of the left ventricular volume changes using high-temporal-resolution cinematic magnetic resonance imaging (CINE MRI) is an alternative approach which is emerging as a potentially more robust and user-independent technique. Here, we investigated the performance of high-temporal-resolution CINE MRI and compared it with ultrasound for the detection of diastolic dysfunction in a mouse model of myocardial infarction. An in-house, high-temporal-resolution, retrospectively gated CINE sequence was developed with a temporal resolution of 1 ms. Diastolic function in mice was assessed using a custom-made, open-source reconstruction package. Early (E) and late (A) left ventricular filling phases were easily identifiable, and these measurements were compared directly with high-frequency, pulsed-wave, Doppler ultrasound measurements of mitral valve inflow. A repeatability study established that high-temporal-resolution CINE MRI and Doppler ultrasound showed comparable accuracy when measuring E/A in normal control mice. However, when applied in a mouse model of myocardial infarction, high-temporal-resolution CINE MRI indicated diastolic heart failure (E/A = 0.94 ± 0.11), whereas ultrasound falsely detected normal cardiac function (E/A = 1.21 ± 0.11). The addition of high-temporal-resolution CINE MRI to preclinical imaging studies enhances the library of sequences available to cardiac researchers and potentially identifies diastolic heart failure early in disease progression.
No takes yet. Share an insight, caveat, or question.
Roberts et al. (2017) studied Diastolic dysfunction (n=21). High-temporal-resolution CINE MRI vs. Doppler ultrasound was evaluated on Detection of abnormal diastolic function based on E/A ratio in infarcted mice (p=0.02). High-temporal-resolution CINE MRI successfully identified diastolic dysfunction in a mouse model of myocardial infarction (E/A = 0.94), whereas Doppler ultrasound failed to detect the impairment (E/A = 1.21).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: