Coherent multi-frequency matched-field processing is investigated using a matched-phase coherent matched-field processor. Its main difference from previous coherent processors is that the relative phases of the Fourier components contained within the recorded signal are not assumed to be known a priori. Rather they are considered free parameters that can be determined using a global functional minimization algorithm. Additionally, this processor uses only the cross-frequency terms, making it less susceptible to the detrimental effects of ambient noise; in one example, this processor shows a five decibel improvement over a similar coherent processor. Along with its increased sensitivity with respect to the broadcast source levels, this coherent processor exhibits superior range resolution as compared with multi-frequency incoherent processors, due to the cross-frequency interference of the vertical eigenmodes. Within this work we explore the efficacy of the algorithms used to determine the relative phases along with the performance of the matched-phase coherent processor itself, performed within the context of data collected during an event from the SWellEx-96 experiment. Performance comparisons between this processor, an incoherent processor, and another coherent processor are demonstrated using this data set.
No takes yet. Share an insight, caveat, or question.
Orris et al. (2000) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: