Key result
Carotid laser Doppler vibrometry with machine learning detects heartbeats with a ~0.96 F1-score vs. ECG.
Why the study?
Heartbeat detection is crucial across clinical fields and laser Doppler vibrometry is a promising non-contact method, motivating an evaluation of machine learning for detecting heartbeats from carotid signals.
Does machine learning applied to non-contact carotid Laser Doppler Vibrometry signals accurately detect heartbeats compared to electrocardiography in healthy adults?
Does machine learning applied to non-contact carotid Laser Doppler Vibrometry signals accurately detect heartbeats compared to electrocardiography in healthy adults?
Effect estimate: f1-score 0.96 for SVM
Machine learning can successfully detect heartbeats from non-contact laser Doppler vibrometry signals, offering a promising alternative for cardiac monitoring when contact sensors are problematic.
Supports non-contact LDV feasibility for beat detection; leaves open validation in larger, diverse cohorts.
Background: Heartbeat detection is a crucial step in several clinical fields. Laser Doppler Vibrometer (LDV) is a promising non-contact measurement for heartbeat detection. The aim of this work is to assess whether machine learning can be used for detecting heartbeat from the carotid LDV signal. Methods: The performances of Support Vector Machine (SVM), Decision Tree (DT), Random Forest (RF) and K-Nearest Neighbor (KNN) were compared using the leave-one-subject-out cross-validation as the testing protocol in an LDV dataset collected from 28 subjects. The classification was conducted on LDV signal windows, which were labeled as beat, if containing a beat, or no-beat, otherwise. The labeling procedure was performed using electrocardiography as the gold standard. Results: For the beat class, the f1-score (f1) values were 0.93, 0.93, 0.95, 0.96 for RF, DT, KNN and SVM, respectively. No statistical differences were found between the classifiers. When testing the SVM on the full-length (10 min long) LDV signals, to simulate a real-world application, we achieved a median macro-f1 of 0.76. Conclusions: Using machine learning for heartbeat detection from carotid LDV signals showed encouraging results, representing a promising step in the field of contactless cardiovascular signal analysis.
No takes yet. Share an insight, caveat, or question.
Antognoli et al. (2020) studied Healthy subjects (n=28). Carotid Laser Doppler Vibrometry (LDV) with Machine Learning vs. Electrocardiography (ECG) was evaluated on Heartbeat detection (beat class) (f1-score 0.96 for SVM). Using a Support Vector Machine on carotid laser Doppler vibrometry signals achieved an f1-score of 0.96 for heartbeat detection when compared to an electrocardiography gold standard.