Key result
Different CT perfusion software packages yield substantially discordant ischemic core and penumbra estimates.
Observational (n=26)
Answers are grounded in this paper and cite their sources.
BACKGROUND AND PURPOSE: Although CT perfusion is a promising tool to support treatment decisions for patients with acute ischemic stroke, it still lacks a standardized method for CTP analysis. The purpose of this study was to assess the variability of the area of infarct core and penumbra as presented in summary maps produced by 2 different software packages. MATERIALS AND METHODS: Forty-one CTP image datasets of 26 consecutive patients who presented with acute ischemic stroke were retrospectively evaluated. Identical image datasets were analyzed by using 2 different commercially available CTP analysis software packages, each representing a mainstream of widely used algorithms: delay-sensitive and delay-insensitive. Bland-Altman analyses were performed to evaluate the level of agreement between the 2 methods in determining the area of infarct core and penumbra area in the summary maps. RESULTS: There was a statistically significant difference in infarct core area (-23.6 ± 25.6 cm(2)) and penumbra area (15.8 ± 25.3 cm(2)) between the 2 software packages. For all the areas presented in the summary maps, the Bland-Altman interval limit of agreement was larger than 100 cm(2). CONCLUSIONS: The infarct core and penumbra area of CTP summary maps generated by 2 commonly used software packages were significantly different, emphasizing the need for standardization and validation of CTP analysis before it can be applied to patient management in clinical practice.
No takes yet. Share an insight, caveat, or question.
Fahmi et al. (2012) conducted an observational in Acute ischemic stroke (n=26). CT perfusion analysis using a delay-sensitive software package vs. CT perfusion analysis using a delay-insensitive software package was evaluated on Level of agreement in determining the area of infarct core and penumbra in summary maps (MD -23.6 ± 25.6 cm2 for infarct core; 15.8 ± 25.3 cm2 for penumbra). CT perfusion summary maps generated by 2 different software packages yielded significantly different infarct core areas (-23.6 ± 25.6 cm2) and penumbra areas (15.8 ± 25.3 cm2).
Synapse has enriched 10 related papers. Consider them for comparative context: