Answers are grounded in this paper and cite their sources.
This research aims to design and develop an elec-tron linear accelerator system and beam diagnostic instruments for natural rubber and polymer research at the Plasma and Beam Physics Research Facility, Chiang Mai University, Thailand. The accelerator con-sists of a DC thermionic electron gun and an S-band standing-wave linac. The system can produce electron beams with the energy range of 0.5 to 4 MeV for the pulse repetition rate of 30 to 200 Hz and the pulse duration of 4 μs. Commissioning of the accelerator system and development of beam diagnostic instru-ments to measure electron beam energy, electron pulse current and electron dose are underway. This contribu-tion presents and discusses on the RF commissioning progress as well as status of design and construction of the beam diagnostic system.
No takes yet. Share an insight, caveat, or question.
Kongmon et al. (2017) studied this question.