Key result
Leadless pacemakers are linked to similar significant TR vs 4.1Fr leads but ~106% higher progression.
Why the study?
While leadless pacemakers and 4.1Fr stylet lumen-less transvenous leads may reduce the risk of tricuspid regurgitation progression compared with conventional leads, the optimal strategy between these two approaches remains unclear.
Does leadless pacemaker implantation compared to a 4.1Fr transvenous right ventricular lead increase the risk of tricuspid regurgitation progression in patients requiring pacemakers?
Cohort (n=217)
Does leadless pacemaker implantation compared to a 4.1Fr transvenous right ventricular lead increase the risk of tricuspid regurgitation progression in patients requiring pacemakers?
Implantation of a 4.1Fr transvenous right ventricular lead may be associated with a lower risk of tricuspid regurgitation progression compared to a leadless pacemaker at 12 months.
Higher TR progression with leadless pacemakers warrants vigilance; leaves open need for randomized confirmation of clinical impact.
BACKGROUND: Tricuspid valve regurgitation (TR) progression is a recognized complication of cardiac-implantable electronic devices. Implanting a leadless pacemaker (LLPM) or using a 4.1Fr stylet lumen-less transvenous lead may lower the risk of TR progression compared to conventional 5-7Fr transvenous leads; however, the optimal strategy remains unclear. This study aimed to evaluate TR progression following those two approaches. METHODS: A retrospective comparison was conducted between patients receiving an LLPM (n = 27) and those implanted with a 4.1Fr transvenous right ventricular lead (n = 190). The primary outcome was the prevalence of significant TR, defined as moderate or severe TR, at 12 months post-implantation. The secondary outcome was the incidence of TR progression, defined as a worsening of ≥1 grade between baseline and 12 months post-implantation. RESULTS: Baseline TR severity did not differ significantly between the two groups. At the 12-month follow-up, the prevalence of significant TR remained comparable between the LLPM and 4.1Fr lead groups (15% vs. 12%, p = 0.54). While most patients in both groups experienced either no change or a one-grade worsening in TR severity, the LLPM group demonstrated a significantly higher incidence of TR progression compared to the 4.1Fr lead group (33% vs. 16%, p = 0.034). Multivariate analysis identified left ventricular ejection fraction <50% as an independent predictor of TR progression (odds ratio 3.05, 95% confidence interval 1.08-8.61, p = 0.036). CONCLUSIONS: Implantation of a 4.1Fr lead in the right ventricular septum may be an optimal strategy to minimize the risk of TR progression following pacemaker implantation.
No takes yet. Share an insight, caveat, or question.
Kawaguchi et al. (2026) conducted a cohort in Pacemaker implantation (n=217). Leadless pacemaker (LLPM) vs. 4.1Fr transvenous right ventricular lead was evaluated on Prevalence of significant TR (moderate or severe) at 12 months post-implantation (p=0.54). Leadless pacemakers showed similar rates of significant tricuspid regurgitation compared to 4.1Fr leads (15% vs 12%, p=0.54) but a higher incidence of TR progression (33% vs 16%, p=0.034).