The power spectral density of surface-relief variations on polished optical surfaces across microscopic through to macroscopic spatial scales is calculated from measurements on substrates that are being produced for the Laser Interferometer Gravitational-Wave Observatory (LIGO). These spectra give a guide to the scattering properties of the surface, which in turn critically influence the performance of LIGO. Measurements obtained by use of a full-aperture interferometer and an interference microscope with two different objectives are combined to produce one-dimensional power spectral density representations of the surfaces across spatial frequencies ranging from 0.1 to 8000 cm(-1). These measurements from different instruments are in good agreement with an analytic power spectrum that varies as nu(-1.5), where nu is the spatial frequency. Some anomalies in the power spectral density spectra can be related to aspects of the polishing process.
No takes yet. Share an insight, caveat, or question.
Walsh et al. (1999) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: