Temperature measurement is required for many applications but can be difficult in some cases. Laser heating or cooling studies demand accurate measurements of temperature changes. A Michelson interferometer configuration has been used to investigate laser heating in solids. An analytical formula was derived to estimate the temperature change from the fringe count by taking into account the temperature dependence of the sample length and refractive index. When 115 mW of a focused Ar+ laser beam (488 nm) passes through a Pr(3+)-doped YAG sample, its temperature increased by 11.7±1.0 K along the beam path due to nonradiative relaxation. The power dependence of the fringe count/movement was recorded. The temperature change was estimated by the interferometric method and is in agreement with that measured by a thermocouple.
No takes yet. Share an insight, caveat, or question.
Farley et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: