A novel encoder with dual displacement resolution is developed by integrating a multiple-grating-scale holographic displacement sensor and a heterodyne interferometer. With suitable arrangement of the measurement system, two effective grating pitches (0.41 μm and 10.62 μm) can be obtained and the theoretical sensitivities of them are 0.9 °/nm and 0.036 °/nm. Meanwhile, the best resolution of the proposed method can be estimated of 0.3 pm and 7.4 pm, respectively. Furthermore, displacement errors of the proposed method can be better than 0.2% for 1 mm displacement measurement. The experimental results showed that the proposed encoder provided high sensitivity, high resolution, and well against environmental disturbance.
No takes yet. Share an insight, caveat, or question.
Hsu et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: