Key result
A combination of second derivative photoplethysmography features classified myocardial infarction patients from healthy controls with 90.6% accuracy, 93.9% sensitivity, and 87.5% specificity.
Why the study?
Can second derivative photoplethysmographic (SDPPG) features accurately distinguish myocardial infarction patients from healthy controls?
Case-Control (n=64)
No
Can second derivative photoplethysmographic (SDPPG) features accurately distinguish myocardial infarction patients from healthy controls?
Second derivative photoplethysmography features show high accuracy, sensitivity, and specificity in distinguishing patients with myocardial infarction from healthy controls.
Hypothesis-generating for photoplethysmography-based myocardial infarction detection; leaves open clinical utility pending prospective validation.
Myocardial infarction (MI) is a common disease that causes morbidity and mortality. The current tools for diagnosing this disease are improving, but still have some limitations. This study utilised the second derivative of photoplethysmography (SDPPG) features to distinguish MI patients from healthy control subjects. The features include amplitude-derived SDPPG features (pulse height, ratio, jerk) and interval-derived SDPPG features (intervals and relative crest time (RCT)). We evaluated 32 MI patients at Pusat Perubatan Universiti Kebangsaan Malaysia and 32 control subjects (all ages 37-87 years). Statistical analysis revealed that the mean amplitude-derived SDPPG features were higher in MI patients than in control subjects. In contrast, the mean interval-derived SDPPG features were lower in MI patients than in the controls. The classifier model of binary logistic regression (Model 7), showed that the combination of SDPPG features that include the pulse height (d-wave), the intervals of "ab", "ad", "bc", "bd", and "be", and the RCT of "ad/aa" could be used to classify MI patients with 90.6% accuracy, 93.9% sensitivity and 87.5% specificity at a cut-off value of 0.5 compared with the single features model.
No takes yet. Share an insight, caveat, or question.
Mahri et al. (2017) conducted a case-control in Myocardial infarction (n=64). Second derivative of photoplethysmography (SDPPG) features vs. Healthy control subjects was evaluated on Classification of myocardial infarction. A combination of second derivative photoplethysmography features classified myocardial infarction patients from healthy controls with 90.6% accuracy, 93.9% sensitivity, and 87.5% specificity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: