In this article, the switching strategy and the remedial control scheme are studied for the cascaded current-source converters (CSCs) fed dual three-phase permanent-magnet synchronous motor (PMSM) variable-speed drives. An optimized space vector modulation (SVM) strategy is proposed to reduce the DC-link current ripple for the proposed drives system. In particular, this switching strategy can work effectively for motor drives under low speed with low back EMF, where there exists a large voltage difference between peak voltage values on the grid side and the motor side. Apart from that, a hybrid fault-tolerant control scheme is also designed for the open-phase fault in dual three-phase PMSM drives system, aiming at achieving small DC-link current ripple and torque ripple, low copper loss, and machine-friendly waveform quality. With the proposed optimized SVM and the hybrid fault-tolerant control strategy, the DC-link current ripple of the cascaded CSCs system can be effectively reduced and good operational performance can be obtained under both normal operation condition and open-phase fault condition. Experimental results are provided to verify the effectiveness of the proposed methods.