This preclinical study describes an experimental model evaluating a 1-mm PTFE microprosthesis as an aortic substitute in rats compared to biological grafts.
The experimental behavior of a 1-mm internal diameter (i.d.) polytetrafluoroethylene (PTFE) microprosthesis, as a substitute for an abdominal aortic segment in the rat, was reviewed. Fifty Wistar rats were divided into four groups: Group I - 12 rats with autotransplant of an abdominal aortic segment (AAS); Group II - 12 rats with allotransplant of an AAS obtained from Long-Evans rats; Group III - 12 rats with xeno-transplant of an AAS taken from rabbit femoral arteries; and Group IV - 14 rats with substitution of an AAS by a 1-mm i.d. PTFE microprosthesis. The rats were sacrificed at different time intervals ranging from five to 360 days, with previous aortography.
No takes yet. Share an insight, caveat, or question.
Padilla et al. (1987) studied this question.