AIM: To demonstrate the feasibility of nanomaterial-based sensors for identifying patterns of exhaled volatile organic compound of end-stage renal disease (ESRD) and study the impact of hemodialysis (HD) on these patterns. PATIENTS & METHODS: Exhaled breath samples were collected from a group of 37 volunteers (26 ESRD HD patients; 11 healthy controls); a third of the samples were randomly blinded for determining the sensitivity/specificity of the method. Discriminant function analysis was used to build a model for discriminating ESRD patients and healthy controls (classification accuracy for blind samples: 80%), based on the signals of the nanomaterial sensors. RESULTS & CONCLUSION: The breath pattern of the ESRD patients approached the healthy pattern during the HD treatment, without reaching it completely. Gas chromatography/mass spectrometry identified four volatile organic compounds as potential ESRD biomarkers. Although this pilot study has yielded encouraging results, additional large-scale clinical studies are required to develop a fast, noninvasive breath test for monitoring HD adequacy in real time.
No takes yet. Share an insight, caveat, or question.
Assady et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: