Magnetic flux leakage (MFL) testing owns the advantages of high inspection sensitivity and stability, but its testing results are always affected by surface roughness. The relationship between the surface roughness ( R a ) and detection signals for surface-breaking cracks is mainly discussed. The existence of roughness magnetic compression effect (RMCE) in present MFL testing is specially pointed out and its relevant theory is also analyzed, which manifest themselves in the compression of MFL signal in its peak value and the baseline drifts mixed with noise. An experimental investigation on surface comparators with different arithmetic average height ( R a ) and artificial notch size, is performed to analyze the effects of surface roughness on detection signals of cracks. The detection limit (DL) of micro-crack is analyzed by comparing the B y noise-signal ratio ( S y ) and peak-peak signals of the cracks. Meanwhile, S y increases with the R a and R S m , in this case, relatively shallow defects cannot be clearly distinguished at determined rough surface. Afterwards, a series of simulations are designed and performed to verify the effects of surface roughness on characteristic B y of the electromagnetic field, and a theoretical DL of micro-crack is presented as: D L = 2 . 8 8 R a + 7 . 0 0