Etching of silicon with molecular fluorine for the micromachining of micro electro mechanical systems (MEMS) has been evaluated. The etching process is carried out in a continuous flow etching system that uses a 25 vol% mixture of F 2 in N 2 and operates at room temperature and atmospheric pressure. Fluorine etches silicon isotropically at a rate of 0.2 µm min −1 and is a viable etchant for bulk silicon micromachining. The F 2 etch results in the formation of pits about 10–50 µm in size within the silicon features and roughness in the micrometer and sub-micrometer length scales. SiO 2 , Pt, Ni, Al and Ta do not etch or roughen after several hours of F 2 exposure. In addition, F 2 does not etch low-stress silicon nitride; a solid layer forms on the silicon nitride surface upon exposure to F 2 that protects the underlying silicon nitride from further attack. In contrast, a commercial XeF 2 etching system etches low-stress silicon nitride with a silicon nitride:silicon selectivity of approximately 1:200. The F 2 etching system is used to release tubes of a MEMS fuel processor that have 2 µm thick low-stress silicon nitride walls.
No takes yet. Share an insight, caveat, or question.
Arana et al. (2007) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: