Why the study?
Physiological signals are often corrupted by noise, and artificial intelligence algorithms typically analyze the entire signal regardless of quality, unlike physicians who search for optimal segments before making an assessment.
A novel deep learning and combinatorial optimization algorithm improves the segmentation and selection of optimal regions in noisy physiological signals like ECG and PCG.
May aid AI segment selection in noisy ECG/PCG; leaves open prospective validation of diagnostic gains.
Physiological signals, such as the electrocardiogram and the phonocardiogram are very often corrupted by noisy sources. Usually, artificial intelligent algorithms analyze the signal regardless of its quality. On the other hand, physicians use a completely orthogonal strategy. They do not assess the entire recording, instead they search for a segment where the fundamental and abnormal waves are easily detected, and only then a prognostic is attempted. Inspired by this fact, a new algorithm that automatically selects an optimal segment for a post-processing stage, according to a criteria defined by the user is proposed. In the process, a Neural Network is used to compute the output state probability distribution for each sample. Using the aforementioned quantities, a graph is designed, whereas state transition constraints are physically imposed into the graph and a set of constraints are used to retrieve a subset of the recording that maximizes the likelihood function, proposed by the user. The developed framework is tested and validated in two applications. In both cases, the system performance is boosted significantly, e.g in heart sound segmentation, sensitivity increases 2.4% when compared to the standard approaches in the literature.
No takes yet. Share an insight, caveat, or question.
Oliveira et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: