Why the study?
Non-invasive neuromodulation of non-compressible internal organs has significant potential for internal organ bleeding and blood-shift in aero/space medicine, but its influence on organ blood flow required investigation.
Does transcutaneous electrical nerve stimulation (TENS) reduce blood flow to non-compressible internal organs in a porcine model?
Does transcutaneous electrical nerve stimulation (TENS) reduce blood flow to non-compressible internal organs in a porcine model?
TENS at 10Hz with abdominal electrodes can significantly decrease blood flow to non-compressible internal organs, suggesting potential utility for internal organ bleeding or blood-shift management.
Animal data on TENS for organ blood flow remain hypothesis-generating; human trials needed before any clinical consideration.
Abstract Non-invasive neuromodulation of non-compressible internal organs has significant potential for internal organ bleeding and blood-shift in aero/space medicine. The present study aims to investigate the potential influences of the non-invasive transcutaneous electrical nerve stimulation (TENS) on multiple non-compressible internal organs’ blood flow. Porcine animal model (n = 8) was randomized for a total of 48 neuromodulation sessions with two different TENS stimulation frequencies (80Hz, 10Hz) and a placebo stimulation. A combination of two different electrode configurations (Abdominal or Abdominal and Hind Limb) were also performed. Intraarterial blood flow measurements were taken during pre and post-stimulation periods at the left renal artery, common hepatic artery, and left coronary artery. Intracranial, and extracranial arterial blood flows were also assessed with digital subtraction angiography. TENS with abdominal-only electrode configurations at 10hz demonstrated significant reductions in average peak blood flow velocity (APV) of the common hepatic artery (p = 0.0233) and renal arteries (p = 0.0493). Arterial pressures (p = 0.0221) were also significantly lower when renal APV was reduced. The outcome of the present study emphasises the potential use of TENS in decreasing the blood flow of non-compressible internal organs when the correct combination of electrodes configuration and frequency is used.
No takes yet. Share an insight, caveat, or question.
Çakmak et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: