Acetaminophen (analgesic) also known as paracetamol, usually used to reduce moderate pain such as headaches, menstrual periods, cold/flu aches and fever. This is one of the pharmaceutical products generally consume and dispose to the environment and become pharmaceutical pollution. This research, study a new approach applying adsorption concept. Thin coated activated carbon (TCAC) for adsorption of acetaminophen was investigated. The TCAC is formulated using Epoxidised Neutral Rubber (ENR-50) and poly(vinyl) chloride (PVC) as binders with activated carbon as an adsorbent, then was coated on white cotton fabric via brushing technique. Characterisation analysis using Scanning Electron Microscope-Energy Dispersive X-ray (SEM-EDX) and Brunauer-Emmett-Teller (BET) analysis were performed. The pore volume and surface area of the TCAC are 0.07 cm 3 g -1 and 64.3 m 2 g -1 , respectively. The TCAC was evaluated through varies parameters including different initial concentrations and temperatures. The amount of acetaminophen as adsorbate, 50 mg L -1 , able to be adsorbed up to 32.43 mg g -1 into TCAC within 5 h. The result of equilibrium and kinetic studies indicated that Langmuir isotherm model and pseudo-second-order, respectively, are best fitted the adsorption of acetaminophen onto TCAC. It was decisive that the adsorption process of acetaminophen on TCAC is spontenoous (G < 0) and exothermic (H < 0) through thermodynamic studies.
No takes yet. Share an insight, caveat, or question.
Shamsudin et al. (2020) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: