Why the study?
Evaluating peripheral sympathetic activity via muscle sympathetic nerve activity requires invasive microneurography, whereas peripheral arterial stiffness allows non-invasive evaluation.
Peripheral arterial stiffness exhibits features of muscle sympathetic nerve activity, suggesting it could serve as a non-invasive surrogate measure for sympathetic activity.
Supports noninvasive MSNA proxy via arterial stiffness; leaves open larger validation trials before practice adoption.
Muscle sympathetic nerve activity (MSNA) is known as an effective measure to evaluate peripheral sympathetic activity; however, it requires invasive measurement with the microneurography method. In contrast, peripheral arterial stiffness affected by MSNA is a measure that allows non-invasive evaluation of mechanical changes of arterial elasticity. This paper aims to clarify the features of peripheral arterial stiffness to determine whether it inherits MSNA features towards non-invasive evaluation of its activity. To this end, we propose a method to estimate peripheral arterial stiffness [Formula: see text] at a high sampling rate. Power spectral analysis of the estimated [Formula: see text] was then performed on data acquired from 15 patients ([Formula: see text] years) who underwent endoscopic thoracic sympathectomy. We examined whether [Formula: see text] exhibited the features of MSNA where its frequency components synchronise with heart and respiration rates and correlates with the low-frequency component of systolic blood pressure. Regression analysis revealed that the local peak frequency in the range of heartbeat frequency highly correlate with the heart rate ([Formula: see text], [Formula: see text]) where the regression slope was approximately 1 and intercept was approximately 0. Frequency analysis then found spectral peaks of [Formula: see text] approximately 0.2 Hz that correspond to the respiratory cycle. Finally, cross power spectral analysis showed a significant magnitude squared coherence between [Formula: see text] and systolic blood pressure in the frequency band from 0.04 to 0.2 Hz. These results indicate that [Formula: see text] inherits the features observed in MSNA that require invasive measurements, and thus [Formula: see text] can be an effective non-invasive substitution for MSNA measure.
No takes yet. Share an insight, caveat, or question.
Muneyasu et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: