Optics-based tracking of civil structures is not new, due to historical application in surveying, but automated applications capable of tracking at rates that capture dynamic effects are now a hot research topic in structural health monitoring. Recent innovations show promise of true non-contacting monitoring capability avoiding the need for physically attached sensor arrays. The paper reviews recent experience using the Imetrum Dynamic Station (DMS) commercial optics-based tracking system on Humber Bridge and Tamar Bridge, aiming to show both the potential and limitations. In particular the paper focuses on the challenges to field application of such a system resulting from camera instability, nature of the target (artificial or structural feature) and illumination. The paper ends with evaluation of a non-proprietary system using a consumer grade camera for cable vibration monitoring to emphasise the potential for lower cost systems where if performance specifications can be relaxed.
No takes yet. Share an insight, caveat, or question.
Brownjohn et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: