The combination of high-mechanical flexibility and high-optical reflectivity makes planar photonic crystal diaphragms excellent mirrors for optical resonators used in fiber-optic pressure sensing. We have developed a standard silicon process to construct a monolithic photonic crystal-based crystalline silicon membrane. We report on three photonic crystal pressure sensors with different compliances, and discuss the following figures of merit: spectral shift sensitivity; optical sensitivity; pressure sensitivity; resolution; and dynamic range. When compared with a sensor made with an oxide diaphragm, each of our sensors is at least an order of magnitude more sensitive, with a spectral shift sensitivity magnitude of up to 8.6 nm/kPa. We show that the fabrication can be tailored to optimize figures of merit depending on the needs of the application.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: