Key result
Ultrasonographic peak systolic velocity showed good linear correlation (r=0.88) with 64-row MDCTA-AVA software for quantifying 50-70% carotid stenosis, with 93% sensitivity and 82% specificity.
Why the study?
Does ultrasonographic peak systolic velocity correlate with 64-row MDCTA in quantifying 50-70% carotid artery stenosis?
Cross-Sectional (n=199)
Does ultrasonographic peak systolic velocity correlate with 64-row MDCTA in quantifying 50-70% carotid artery stenosis?
Ultrasonographic peak systolic velocity shows a strong linear correlation with 64-row MDCTA-AVA software for quantifying 50-70% carotid artery stenosis.
Answers are grounded in this paper and cite their sources.
Supports noninvasive ultrasonographic quantification of moderate carotid stenosis; leaves open prospective outcome validation before wider adoption.
Purpose. To correlate ultrasonographic peak systolic velocity (US-PSV) and 64-row multidetector computed tomography angiography (MDCTA) with advanced vessel analysis (AVA) software in the quantification of 50-70% carotid artery stenosis. Materials and methods. 199 consecutive patients (247 arteries) with internal carotid artery (ICA) or third proximal bifurcation stenosis. Each patient was studied by duplex US (DUS) and 64-row MDCTA with AVA software. Results. DUS showed PSV measurements less than 125 cm/s in 51 carotid stenosis and a value greater than this in 196 arteries. 64-row MDCTA AVA software showed a grade of stenosis less than 50% in 42 carotid arteries while a greater 70% was found in 4 carotid arteries; then, carotid arteries with stenosis percentage between 50% and 70% were 201. Linear regression analysis showed a good linear correlation (r = 0.88) between MDCTA-AVA software percentage stenosis and PSV: between 50% grade of stenosis and PSV value corresponding to 133,6 cm/sec and between 70% stenosis and PSV value corresponding to 268 cm/sec. The sensitivity, specificity, positive predictive value(PPV), negative predictive value(NPV) of this analysis were 93%, 82%, 97%, 75%, respectively. Conclusion. Linear correlation between PSV data and grade of stenosis from 50% to 70% obtained with 64-row MDCTA AVA software. Main PSV value corresponding to 50% and 70% grade of stenosis at AVA analysis.
No takes yet. Share an insight, caveat, or question.
Stefanini et al. (2012) conducted a cross-sectional in Internal carotid artery (ICA) or third proximal bifurcation stenosis (n=199). Ultrasonographic peak systolic velocity (US-PSV) vs. 64-row MDCTA with advanced vessel analysis (AVA) software was evaluated on Correlation between MDCTA-AVA software percentage stenosis and PSV (r = 0.88). Ultrasonographic peak systolic velocity showed good linear correlation (r=0.88) with 64-row MDCTA-AVA software for quantifying 50-70% carotid stenosis, with 93% sensitivity and 82% specificity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: