We investigate phase-modulated analog photonic link performance using interferometric detection with a Mach- Zehnder interferometer (MZI) under different bias conditions and a high-power high-linearity modified unitraveling carrier (MUTC) photodiode (PD). Expressions for radio frequency (RF) small signal gain and the optimal MZI bias point for RF gain are derived, and noise figure (NF) and third-order spurious free dynamic range (SFDR3) are analyzed. Using a 28-μm-diameter MUTC single PD with 23 dBm RF output power under 155-mA saturation current at 10 GHz, we measured a record-high link gain of 25 dB, 18 dB NF, and 114 dB · Hz2/3SFDR3at 130 mA photocurrent with an optimally biased MZI. By using a 24-μm-diameter balanced MUTC PD pair with 21 dBm RF output power at 108 mA at 10 GHz, we obtained a 16 dB link gain, 16 dB NF, and 118 dB · Hz2/3DR3at 100 mA total dc photocurrent when the MZI was biased at quadrature. The RF gain at both MZI bias points is in good agreement with our calculations.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: