This paper presents a description and analysis of a full-bridge converter with a novel passive and robust auxiliary circuit for zero-voltage-switching (ZVS) operation. A generalized time-domain state-space analysis is provided to describe the steady-state behavior of the auxiliary circuit. Complete comparison between the well-known single-inductor auxiliary circuit, and the proposed one is presented. For a similar peak current in the auxiliary branch, needed for ZVS, a minimum of 20% reduction in rms current is achieved to decrease the conduction losses in the power switches and in the auxiliary circuit. Also, 65% reduction in switching frequency variation is obtained. This narrower frequency range reduces the need for very high-frequency operation and the associated gate driver losses as well as the difficulty of electromagnetic interference (EMI) filter design. All the theoretical results are experimentally verified.
No takes yet. Share an insight, caveat, or question.
Safaee et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: