The output power from three Gunn oscillators was combined using a short-slot coupler in conjunction with high-level injection locking with the power combining efficiency of ahout 100 percent at 9.7 GHz. Using the 3-oscillator structure as the building block, we constructed (3/sup 2/ = )9-oscillator corporate structure and (2X4+1=)9- and (2X6+1 = )13-oscillator tandem structures to demonstrate power combining efficiencies of 92, 95, and 93 percent, respectively, at 9.6 GHz.
No takes yet. Share an insight, caveat, or question.
Mizushina et al. (1980) studied this question.