We demonstrate application of high-speed swept source optical coherence tomography for vessel visualization in the anterior segment of the human eye. The human corneo-scleral junction and sclera was imaged in vivo. Imaging was performed using a swept source OCT system operating at 1050nm wavelength range and 100kHz A-scan rate. The high imaging speed enables generation of 3D depth-resolved vasculature maps. The vessel visualization method revealed the rich vascular system in the conjunctiva and episclera. Full Text: PDF References: D. Huang et al., "Optical coherence tomography", Science 254, 1178 (1991). [CrossRef] W. Drexler, J. G. Fujimoto (ed.), Optical Coherence Tomography. Technology and Applications (Springer, Berlin-Heidelberg 2008). A.M. Zysk, A. L. Oldenburg, D.L. Marks, F.T. Nguyen, S.A. Boppart, "Optical coherence tomography: a review of clinical development from bench to bedside", J. Biomed. Opt. 12, 051403 (2007). [CrossRef] Y. Wang, A. Fawzi, O. Tan, J. Gil-Flamer, D. Huang, "Retinal blood flow detection in diabetic patients by Doppler Fourier domain optical coherence tomography", Opt. Exp. 17, 4061 (2009). [CrossRef] M. Pircher, C.K. Hitzenberger, U. Schmidt-Erfurth, " Polarization sensitive optical coherence tomography in the human eye", Prog. Ret. Eye Res. 30, 431 (2011). [CrossRef] M. Wojtkowski, "High-speed optical coherence tomography: basics and applications", Appl. Opt. 49, D30 (2010). [CrossRef] J. A. Izatt et al., "Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence Tomography", Arch. Ophthalmol. 112, 1584 (1994). [CrossRef] M. Gora et al., "Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range", Opt. Exp. 17, 14880 (2009). [CrossRef] B. Potsaid et al., "Ultrahigh speed 1050nm swept source / Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second", Opt. Exp. 18, 20029 (2010). [CrossRef] Y. Yasuno et al., "Three-dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments", Opt. Exp. 13, 10652 (2005). [CrossRef] D.R. Anderson, Am. J. Ophthalmol. 108, 485 (1989). R.K. Wang, L. An, P. Francis, D.J. Wilson, "Doppler optical micro-angiography for volumetric imaging of vascular perfusion in vivo", Opt. Exp. 17, 8926 (2009). [CrossRef] B.J. Vakoc et al., "Three-dimensional microscopy of the tumor microenvironment in vivo using optical frequency domain imaging", Nature Med. 15, 1219 (2009). [CrossRef] K. Bizheva, N. Hutchins, L. Sorbara, A.A. Moayed, T. Simpson, "In vivo volumetric imaging of the human corneo-scleral limbus with spectral domain OCT", Biomed. Opt. Exp. 2, 1794 (2011). [CrossRef] L. Kagemann et al., "Identification and Assessment of Schlemm's Canal by Spectral-Domain Optical Coherence Tomography", Invest. Ophthalmol. Vis. Sci. 51, 4054 (2010). [CrossRef] L. Kagemann et al.,"3D visualization of aqueous humor outflow structures in-situ in humans", Exp. Eye Res., 93, 308 (2011). [CrossRef] P. Li et al., "In vivo microstructural and microvascular imaging of the human corneo-scleral limbus using optical coherence tomography", Biomed. Opt. Exp. 2, 3109 (2011). [CrossRef] M.A. Choma, M.V. Sarunic, Ch. Yang, J.A. Izatt, "Sensitivity advantage of swept source and Fourier domain optical coherence tomography", Opt. Exp. 11, 2183 (2003). [CrossRef]
No takes yet. Share an insight, caveat, or question.
Grulkowski et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: