Selected portions of the first stage stationary inlet nozzle, shroud, and rotor of the AiResearch TFE 731-2 turbine were instrumented with thin-film heat-transfer gages and heat-flux measurements were performed using a shock tunnel as a source of high-temperature, high-pressure gas. Experiments were performed over a range of Reynolds numbers, based on mid-annular stator chord, from 1.6 × 105 to 3.1 × 105 and corrected speeds from approximately 70–106 percent. The full-stage heat-flux results are compared to our previous measurements obtained with a stator only, in the absence of a rotor. The previous results are in good agreement with the full-stage data for the tip end-wall region, but they are significantly less than the full-stage results for the stator airfoil. Pressure measurements were obtained throughout the model and these results are shown to be in excellent agreement with the steady-state rig data supplied to us by AiResearch for this turbine. Heat-flux measurements are also presented for the stationary shroud as a function of rotor mid-annular chord. The shroud heat-flux data are shown to be in excess of the rotor blade results. Rotor-tip heat-flux measurements are shown to be slightly greater than the shroud results.
No takes yet. Share an insight, caveat, or question.
Dunn et al. (1982) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: