Why the study?
Gold-standard LV catheterization for cardiac monitoring is invasive, limiting its applicability, whereas non-invasive ballistocardiography requires mechanistic links to changes in P-V loops and cardiac function.
Does mechanism-driven modeling of BCG signals accurately reflect changes in cardiac function (LV contractility) in pre-clinical swine models?
Does mechanism-driven modeling of BCG signals accurately reflect changes in cardiac function (LV contractility) in pre-clinical swine models?
Answers are grounded in this paper and cite their sources.
Mechanism-driven mathematical modeling can successfully predict changes in ballistocardiography signals corresponding to reduced left ventricular contractility, supporting its potential for non-invasive cardiac monitoring.
Left ventricular (LV) catheterization provides LV pressure-volume (P-V) loops and it represents the gold standard for cardiac function monitoring. This technique, however, is invasive and this limits its applicability in clinical and in-home settings. Ballistocardiography (BCG) is a good candidate for non-invasive cardiac monitoring, as it is based on capturing non-invasively the body motion that results from the blood flowing through the cardiovascular system. This work aims at building a mechanistic connection between changes in the BCG signal, changes in the P-V loops and changes in cardiac function. A mechanism-driven model based on cardiovascular physiology has been used as a virtual laboratory to predict how changes in cardiac function will manifest in the BCG waveform. Specifically, model simulations indicate that a decline in LV contractility results in an increase of the relative timing between the ECG and BCG signal and a decrease in BCG amplitude. The predicted changes have subsequently been observed in measurements on three swine serving as pre-clinical models for pre- and post-myocardial infarction conditions. The reproducibility of BCG measurements has been assessed on repeated, consecutive sessions of data acquisitions on three additional swine. Overall, this study provides experimental evidence supporting the utilization of mechanism-driven mathematical modeling as a guide to interpret changes in the BCG signal on the basis of cardiovascular physiology, thereby advancing the BCG technique as an effective method for non-invasive monitoring of cardiac function.
No takes yet. Share an insight, caveat, or question.
Zaid et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: