AIM: To perform meta-analysis of the use of Endocuff during average risk screening colonoscopy. METHODS: Scopus, Cochrane databases, MEDLINE/PubMed, and CINAHL were searched in April 2016. Abstracts from Digestive Disease Week, United European Gastroenterology, and the American College of Gastroenterology meeting were also searched from 2004-2015. Studies comparing EC-assisted colonoscopy (EAC) to standard colonoscopy, for any indication, were included in the analysis. The analysis was conducted by using the Mantel-Haenszel or DerSimonian and Laird models with the odds ratio (OR) to assess adenoma detection, cecal intubation rate, and complications performed. RESULTS: = 0.44). EAC was associated with a higher risk of complications, most commonly being superficial mucosal injury without higher frequency for perforation. CONCLUSION: The use of an EC on colonoscopy appears to improve pre-cancerous polyp detection without any difference in cecal intubation rates compared to standard colonoscopy.