Answers are grounded in this paper and cite their sources.
This randomized, controlled trial involving 316 patients in the home setting found no difference in the rate of phlebitis and/or occlusion among patients for whom a peripheral intravenous catheter was routinely resited at 72-96 hours and those for whom it was replaced only on clinical indication (76.8 events per 1,000 device-days vs 87.3 events per 1,000 device-days; P = .71). There were no bloodstream infections.
No takes yet. Share an insight, caveat, or question.
Donk et al. (2009) studied this question.