Answers are grounded in this paper and cite their sources.
The homogenised failure surfaces obtained through the simple micro-mechanical model developed in the first part of the paper are here used for the analysis of in-plane loaded masonry walls. Both upper and lower bound homogenised limit analyses are employed for treating meaningful structural cases, namely a deep beam and a set of shear walls . Detailed comparisons between the experimental data and numerical results obtained using both a heterogeneous and a homogenised approach are also presented. The examples show the efficiency of the homogenised technique with respect to: (1) accuracy of the results; (2) reduced number of finite elements required; (3) independence of the mesh, at a structural level, from the actual texture of masonry. A final example on a large scale wall is presented with the aim to show an engineering application of the proposed approach.
No takes yet. Share an insight, caveat, or question.
Milani et al. (2005) studied this question.