Why the study?
Aortic regurgitation after TAVR predicts survival, but no independent quantitative comparison of aortic regurgitation among commercially available transcatheter heart valves had been performed.
Does the choice of transcatheter heart valve affect the degree of acute aortic regurgitation following TAVR?
Does the choice of transcatheter heart valve affect the degree of acute aortic regurgitation following TAVR?
Quantitative videodensitometry reveals significant differences in acute aortic regurgitation among 11 contemporary TAVR devices, with Lotus and ACURATE neo2 showing the lowest regurgitation rates.
Background Aortic regurgitation (AR) following transcatheter aortic valve replacement (TAVR) is a major predictor of short- and long-term survival. Thus far, no independent quantitative comparison of AR among commercially available transcatheter heart valves (THVs) has been performed. Objectives We sought to assess and compare the degree of acute AR following TAVR between 11 commercially available THVs and update our previous multicenter, pooled analysis. Methods Analyses were performed by an independent academic core lab using quantitative videodensitometry, a technique relying solely on the aortogram acquired after TAVR. The pooled analysis ( n = 2665) included data from the initial cohort of 7 valves (Lotus [ n = 546], Evolut PRO [ n = 95], SAPIEN 3 [ n = 397], Evolut R [ n = 295], SAPIEN XT [ n = 239], ACURATE neo [ n = 120], and CoreValve [ n = 532]) to which data from 4 new valves were added (ACURATE neo2 [ n = 120], Myval [ n = 108], VitaFlow [ n = 105], and Venus-A [ n = 113]). Results The Lotus valve had the lowest mean AR (3.5% ± 4.4%) followed by ACURATE neo2 (4.4% ± 4.8%), VitaFlow (6.1% ± 6.4%), Myval (6.3% ± 6.3%), Evolut PRO (7.4% ± 6.5%), SAPIEN 3 (7.6% ± 7.1%), Evolut R (7.9% ± 7.4%), SAPIEN XT (8.8% ± 7.5%), Venus-A (8.9% ± 10%), ACURATE neo (9.6% ± 9.2%), and CoreValve (13.7% ± 10.7%, analysis of variance P -value < .001). The only valves that statistically differed from all their counterparts were Lotus, with the lowest regurgitation in comparison to other valves except ACURATE neo2, which had less regurgitation compared with SAPIEN 3, Evolut R, SAPIEN XT, Venus-A, ACURATE neo, and CoreValve. CoreValve had the highest mean of AR, with the rates of moderate/severe AR: ACURATE neo2 (1.7%), Lotus (2.2%), Myval (2.8%), VitaFlow (4.7%), Evolut PRO (5.3%), SAPIEN 3 (8.3%), Evolut R (8.8%), SAPIEN XT (10.9%), ACURATE neo (11.3%), Venus-A (14.2%), and CoreValve (30.1%)—χ 2 P -value < .001. Conclusions In this updated pooled analysis, the Lotus valve had the lowest mean AR, while ACURATE neo2 had the lowest rate of moderate/severe AR. Myval, VitaFlow, and Venus-A THVs showed promising results.
No takes yet. Share an insight, caveat, or question.
Abdelshafy et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: