This paper describes the configuration and operation of a seven-cavity linear transformer driver (LTD) system. This LTD system is configured to deliver ~1 MV and 125 kA into a critically damped load. A detailed transmission line model coupled to particle-in-cell simulations is used to assess the system electrical performance. The evolution of the electron power flow in negative polarity is simulated, and the impact of this flow on the operation of the system with a large-area hollow electron beam diode is examined. The simulation results are compared with available electrical measurements and with dose rate measurements where a flash X-ray pulse is produced by an annular electron beam diode. These comparisons suggest that the LTD system meets the design specifications and is a robust pulsed power architecture. Additionally, the positive polarity operation for the LTD system driving a rod-pinch diode load is modeled to further assess the utility of the LTD system