Key result
Sequential treprostinil and axial-flow MCS reduces PVR ~84%, enabling heart-kidney transplantation.
Case Report (n=1)
Sequential use of intravenous treprostinil and temporary axial-flow mechanical circulatory support can successfully reduce pulmonary vascular resistance in patients with D-TGA and a failing systemic right ventricle to allow for orthotopic heart transplantation.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Bravo‐Jaimes et al. (2022) conducted a case report in D-transposition of the great arteries with advanced heart and kidney failure (n=1). Temporary axial-flow mechanical circulatory support (Impella 5.5) and intravenous treprostinil vs. Baseline hemodynamics was evaluated on Pulmonary vascular resistance (WU). Sequential use of intravenous treprostinil and a temporary axial-flow device successfully reduced pulmonary vascular resistance from 12.6 to 2 WU, enabling successful orthotopic heart and kidney transplantation.