Why the study?
Can an implantable cardioverter/defibrillator with a nonepicardial triple-electrode lead system successfully defibrillate patients with refractory VT/VF?
Can an implantable cardioverter/defibrillator with a nonepicardial triple-electrode lead system successfully defibrillate patients with refractory VT/VF?
An implantable cardioverter/defibrillator with a nonepicardial triple-electrode lead system can successfully achieve endocardial defibrillation, potentially reducing the surgical risks associated with epicardial systems.
Answers are grounded in this paper and cite their sources.
Supports feasibility of nonepicardial triple-electrode ICDs in refractory VT/VF; leaves open comparative efficacy versus epicardial systems.
We evaluated the early clinical performance of an implantable cardioverter/defibrillator with a nonepicardial lead system in patients with refractory ventricular tachycardia or ventricular fibrillation. Ten patients, mean age 67 years, mean left ventricular ejection fraction 35%, refractory to 5 +/- 2 antiarrhythmic drugs and with a history of prior cardiac surgery (7 patients), severe lung disease (2 patients), or renal failure (1 patient) underwent device and lead system implant. A tripolar electrode catheter with one sensing electrode and two defibrillating electrodes was placed in the right ventricular apex and a left thoracic submuscular patch electrode was used in an epicostal location. Defibrillation energy threshold was determined using dual- or triple-electrode configurations. Optimal patch electrode location was determined after temporary use of a cutaneous patch electrode prior to cardioverter/defibrillator implant. Electrophysiologic studies were performed before discharge and after 2 to 3 months to assess device function. Percutaneous insertion and placement of the electrode catheter was achieved in all patients. Defibrillation energy threshold testing was done using 1 to 4 (mean, 2.7) electrode configurations per patient and required 6 to 21 (mean, 13) ventricular fibrillation inductions and 8 to 56 (mean, 22) shocks per patient. In all patients, lowest reliable defibrillation energy threshold was obtained with a triple-electrode configuration (right ventricular common cathode with right atrial and thoracic patch as dual anodes) and bidirectional shocks (mean, 18 +/- 5 J). Optimal patch electrode position could be determined in 9 of 10 patients, and these 9 patients had cardioverter/defibrillator implant. Ventricular fibrillation termination with the first delivered shock at electrophysiologic study was documented in all patients. There was no perioperative mortality in device-implanted patients. Postoperative electrophysiologic studies before discharge (9 patients) and at 3 months (8 patients) continued to demonstrate successful defibrillation by the first device shock. During follow-up (range, 2 to 10 months; mean, 6 +/- 3 months), spontaneous device discharges occurred in 4 patients with inappropriate shocks due to electrode catheter fracture being documented in 1 patient. Antiarrhythmic drug therapy was withdrawn in 6 patients and reduced in 3 patients. We conclude, based on our preliminary experience, that an implantable cardioverter/defibrillator can be successfully used with a nonepicardial lead system for endocardial defibrillation in many patients. This lead system can be used with currently available pulse generators and should be considered at cardioverter/defibrillator implantation. It can be anticipated to reduce patient risk and hospital costs associated with this procedure.
No takes yet. Share an insight, caveat, or question.
Sanjeev Saksena (1989) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: