Answers are grounded in this paper and cite their sources.
A nonmachinery based system using gravity dependent flow for the treatment and reinfusion of ascitic fluid was developed, and its usefulness was assessed. In a preliminary study using bovine plasma, samples with protein concentrations below 5.0 g/dl were found to be treatable with this system. Bovine plasma containing blood, prepared to 0.5% hematocrit and with a protein concentration of 3.0 g/dl, was also treatable. We conducted a clinical study of 1,799 treatment sessions (1,495 using a machinery based system and 304 using a nonmachinery based system) of 343 patients with ascites refractory to various treatments. The recovery ratio of protein from the original ascitic fluid was 96% using the nonmachinery based system and 77% with the machinery based system (p < 0.01). Of 253 continuous reinfusions of ascitic fluid using the nonmachinery based system, the original ascitic fluid at protein concentrations below 2.5 g/dl was treatable. Original ascitic fluid below a hematocrit of 0.7% (protein concentration, 1.4 g/dl) was also treatable. This new procedure was simple and time and labor saving; the high recovery ratio of protein also demonstrated the usefulness of the new system.
No takes yet. Share an insight, caveat, or question.
Katoh et al. (1997) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: