Primers for herpes simplex virus type 1 (HSV 1)-specific loop-mediated isothermal amplification (LAMP) method amplified HSV-1 DNA, while HSV-2-specific primers amplified only HSV-2 DNA; no LAMP products were produced by reactions performed with other viral DNAs. The sensitivities of the HSV-1- and HSV-2-specific LAMP methods, determined by agarose gel electrophoresis, reached 500 and 1,000 copies/tube, respectively. The turbidity assay, however, determined the sensitivity of the HSV-1- and HSV-2-specific LAMP methods to be 1,000 and 10,000 copies/tube, respectively. After initial validation studies, 18 swab samples (in sterilized water) collected from patients with either gingivostomatitis or vesicular skin eruptions were examined. HSV-1 LAMP products were detected by agarose gel electrophoresis in the 10 samples that also demonstrated viral DNA detection by real-time PCR. Nine of these 10 samples exhibited HSV-1 LAMP products by turbidity assay. Furthermore, both the agarose gel electrophoresis and the turbidity assay directly detected HSV-1 LAMP products in 9 of the 10 swab samples collected in sterilized water. Next, we examined the reliability of HSV type-specific LAMP for the detection of viral DNA in clinical specimens (culture medium) collected from genital lesions. HSV-2 was isolated from all of the samples and visualized by either agarose gel electrophoresis or turbidity assay.
No takes yet. Share an insight, caveat, or question.
Enomoto et al. (2005) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: