This paper discusses some of the electromagnetic-compatibility issues concerning the use of power lines for communication. Based on a series of measurements performed in a laboratory environment and in the field, five different types of interactions between communication and end-user equipment are distinguished. Measurement examples are shown for several of these types. It is concluded that the creation of a low-impedance path by end-user equipment is the main cause of interference.