Why the study?
Does the elimination of atrial booster pump action reduce hemodynamic performance in patients with aortic or mitral stenosis?
Does the elimination of atrial booster pump action reduce hemodynamic performance in patients with aortic or mitral stenosis?
Well-timed atrial booster pump action significantly contributes to left ventricular filling and overall hemodynamic performance in patients with aortic and mitral stenosis.
Preserving AV synchrony may aid hemodynamics in aortic/mitral stenosis; leaves open relevance to contemporary device strategies.
This study was designed to assess atrial booster pump action in valvular heart disease and to dissect booster pump from reservoir-conduit functions. In five patients with aortic stenosis and six with mitral stenosis, sequential atrioventricular (A-V) pacing was instituted during the course of diagnostic cardiac catheterization. Continuous recording of valvular gradient allowed estimation of flow for each cardiac cycle by transposition of the Gorlin formula. Left ventricular ejection time and left ventricular stroke work in aortic stenosis or left ventricular mean systolic pressure in mitral stenosis were also determined. Control observations were recorded during sequential A-V pacing with well-timed atrial systole. Cardiac cycles were then produced with no atrial contraction but undisturbed atrial reservoir function by intermittently interrupting the atrial pacing stimulus during sequential A-V pacing. This intervention significantly reduced valvular gradient, flow, left ventricular ejection time, and left ventricular mean systolic pressure or stroke work. Cardiac cycles were then produced with atrial booster action eliminated by instituting synchronous A-V pacing. The resultant simultaneous contraction of the atrium and ventricle not only eliminated effective atrial systole but also placed atrial systole during the normal period of atrial reservoir function. This also significantly reduced all the hemodynamic measurements. However, comparison of the magnitude of change from these two different pacing interventions showed no greater impairment of hemodynamic state when both booster pump action and reservoir function were impaired than when booster pump action alone was impaired. The study confirms the potential benefit of well placed atrial booster pump action in valvular heart disease in man.
No takes yet. Share an insight, caveat, or question.
Heidenreich et al. (1970) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: